Aquasol – Test Kit Range

Total Hardness Test Kit

When water passes through or over deposits such as limestone, the levels of ca2+, mg2+, and hco3– ions present in the water greatly increase and cause the water to be classified as hard water. Hardness in water is caused by dissolved minerals and calcium and magnesium ions are usually present in significant concentration along with other divalent ions. Hardness creates scale deposit problem which lead to energy loss in different industrial systems ,such as boiler, cooling system, cause scale formation in plumbing, heating appliances, and boilers. Measuring total hardness is essential to monitor – softener, demineralization, RO plant, softening processes, etc. Our AQUASOL hardness range is one of the largest available in the market today. It is a premium kit and finds use in almost all industries, where water is the most important ingredient/parameter.

Code Range No of test
AE-201 2-40, 5-100 mg/l as caco3 250
AE-211 2-40, 25-500 mg/l as caco3 250
AE-221 5-100, 25-500 mg/l as caco3 250
AE-231 1-20, 5-100 mg/l as caco3 250
AE-241 50-1000 mg/l as caco3 250
AE-501 2-40, 5-100 mg/l as caco3 500
AE-511 2-40, 25-500 mg/l as caco3 500
AE-521 5-100, 25-500 mg/l as caco3 500
AE-531 1-20, 5-100 mg/l as caco3 500
AE-541 50-1000 mg/l as caco3 500

Product Video:  

Chlorine / Free chlorine Test Kit

Chlorine is the most widely used oxidizing biocide today for disinfection of domestic water supplies as also for the removal of tastes and odours from water. The amount of chlorine required to be added in a water system is determined by chlorine demand, contact time, pH and temperature of the water. Chlorine residual in drinking water indicates that disinfection has been achieved by chlorine and bacteria/viruses that cause diarrheal disease have been eliminated. Also, the water is protected from recontamination during storage. Our AQUASOL chlorine test is available in three different types, DPD method, Iodometric method and OT method. The kit gives very reliable results. The endpoint is very sharp and easily discernable by the user. Even a shop floor worker will be able to get desired results with our test kit.

Code Range No of test
AE-205 0.1-2.0 mg/l as chlorine 200
AE-215 0.2-4 mg/l as chlorine 200
AE-246 10-200 mg/l as chlorine 300
AE-246l 1-20 mg/l as chlorine 300

Chlorine / Free chlorine Test Kit

Chlorine is the most widely used oxidizing biocide today for disinfection of domestic water supplies as also for the removal of tastes and odours from water. The amount of chlorine required to be added in a water system is determined by chlorine demand, contact time, ph and temperature of the water. Chlorine residual in drinking water indicates that disinfection has been achieved by chlorine and bacteria / viruses that cause diarrheal disease have been eliminated. Also the water is protected from recontamination during storage. Our AQUASOL single reagent based Free Chlorine Test Kit (O.T.) comes with a scientifically designed Colour Comparator. The economical Comparator based design not only discern colours easily but also helps to achieve results quickly. This Free Chlorine Test Kit (AE-409) is a cost effective and convinent method for periodic monitoring free chlorine in water.. The end point is very sharp and easily discernable by the user. Even a shop floor worker will be able to get desired results with our test kit.

Code Range No of test
AE-409 0.05 – 5.0 mg/l as chlorine 1000

Alkalinity Test Kit

The alkalinity of water is capacity of water to neutralise acid to desired ph. It is mainly a sum of carbonate, bicarbonate and hydroxide ions. Salts of weak acids like borate, silicate and phosphate may also contribute to alkalinity. Alkalinity is important in the treatment of potable water, waste water, boiler and cooling water. Our alkalinity kit is available in two ranges & a very easy to use test to gives reliable results.

Code Range No of test
AE-204 10-200, 100-2000 mg/l as caco3 300
AE-214 5-100, 25-500 mg/l as caco3 300

Chloride Test Kit

Chloride ions are one of the major inorganic anions in water and wastewater. Although high concentrations of chloride in water are not known to be toxic to humans, they may corrode metal pipes. It is essential to monitor chloride concentration in boiler systems to prevent damage of metal parts. In high levels, chloride can corrode stainless steel and be toxic to plant life. Therefore chloride is one of the very important parameters, which is frequently tested and our AQUASOL kit, makes testing easy, simple at the same time accurate.

Code Range No of test
AE-203 10-200, 50-1000 mg/l as chloride 300
AE-213 2-40, 5-100 mg/l as chloride 300
AE-213L 1-20 mg/l as chloride 300

Product Video:

Calcium Hardness Test Kit

Calcium hardness is caused by the presence of calcium ions in the water. Calcium salts can be readily precipitated from water and high levels of calcium hardness tend to promote scale formation in the water system. Calcium hardness is an important control test in industrial water systems such as boilers and steam raising plants. Our kit tests even high levels of calcium in water.

Code Range No of test
AE-202 5-100 mg/l as caco3 300
AE-212 25-500 mg/l as caco3 300

Dissolved Oxygen Test Kit

Dissolved oxygen (do) refers to the volume of oxygen that is present in water. Do is important for maintenance of sewage treatment units. D.o. is essential for the aquatic plant and animal life. Do is detrimental in boiler systems because it leads to corrosion in boiler systems. Do analysis measures the amount of gaseous oxygen (o2) dissolved. In an aqueous solution DO measurement is a tricky business, but our kit makes testing easy and simple.

Code Range No of test
AE-do8 0.5-8.0 mg/l as O2 250

Product Video:  

Ammonium Test Kit

Ammonia is present in variable concentrations in many surface and ground water supplies. It is rapidly oxidized by certain bacteria, in natural water systems, to nitrite and nitrate – a process that requires the presence of dissolved oxygen. Ammonia, being a source of nitrogen is also a nutrient for algAE and other forms of plant life and thus contributes to overloading of natural systems and cause pollution. Ammonia is important to be tested in fisheries. Our AQUASOL ammonia test is based on colour comparison and results obtained are easily discernable.

Code Range No of test
AE-307 0.5, 1.0, 2.0, 4.0, 6.0, 8.0 mg/l as NH4 250
AE-317 0.05, 0.1, 0.25, 0.5, 0.75, 1.0 mg/l as NH4 100

Nitrite Test Kit

Nitrites occur in water as an intermediate product in the biological breakdown of organic nitrogen, being produced either through the oxidation of ammonia or the reduction of nitrate. The presence of large quantities of nitrites is indicative of waste water pollution. Low range nitrite estimation is useful for drinking water analysis. Nitrite is added to control corrosion in closed cooling systems. We have two kits for nitrite one a very low range, especially for drinking and the higher one for waste water. Our AQUASOL kits are based on colour comparison. They are very simple and convenient to use.

Code Range No of test
AE-207 5-100, 50-1000 mg/l as NaNO2 300
AE-217 0.05,0.1,0.2,0.3,0.4,0.5,0.6,0.7,0.8 mg/l as NO2 400

Acidity Test Kit

The acidity of water is the capacity of water to neutralize base to desired ph. Acidity is caused by weak organic acids and strong mineral acids. It indicates corrosion of water. This AQUASOL water test is a titration test and is extremely easy and convenient and gives accurate results.

Code Range No of test
AE-264 10-200 & 100-2000 mg/l as caco3 300

Iron Test Kit

Iron is a naturally occurring mineral found in water especially groundwater which has come in contact with iron-containing rock or soil. Insoluble iron can clog valves and strainers and can cause excessive sludge build up in low lying areas of a water system. It also leads to boiler deposits that can cause tube failure. Suspended or dissolved iron coming in the feed water will also deposit on the boiler metal. Checking iron in boiler and cooling water helps to monitor corrosion level in water. AQUASOL iron test gives a clear red colour result which is then compared with the colour chart provided.

Code Range No of test
AE-303 0.0,0.05,0.1,0.3,0.4,0.5,0.7,1.0,1.5,2.0 mg/l as Fe 175
AE-313 0,2,4,6,8,10 mg/l as iron 175

Product Video:  

Carbon Dioxide Test Kit

Carbon dioxide can react with water to form carbonic acid (h2co3). Carbonic acid will cause corrosion in steam and return lines. Carbon dioxide can originate from condenser air leakage or bicarbonate (hco3) alkalinity in the feed water. Our AQUASOL test for carbon dioxide is a titrimetric kit, packaged with standardized reagents ready to use, convenient and accurate.

Code Range No of test
AE-403 2 – 40 & 10 – 200 as co2 300

PH Test Kit

Ph is the standard measure of how acidic or alkaline a solution is. It is a measure of the hydrogen ion concentration in solution. Ph is important because chemical processes take place when water has a certain ph. A ph indicator, giving different colors at different ph is a simple and reliable method to read ph for routine monitoring. Our AQUASOL ph water test kit comprises of a universal indicator, giving clear colours which match the colour chart perfectly. An extremely easy to use product, it finds usage in almost all processes.

Code Range No of test
AE-306 4 to 10 250

Fluoride Test kit

Fluoride occurs naturally in all types of water. Typically, surface waters and seawaters have low concentration of fluoride while groundwater may contain high levels of fluoride as it may be exposed to many inorganic fluoride-containing minerals. Fluoride salts are also frequently encountered in many industrial applications. Fluoride is important in drinking water as excessive fluoride cause mottling. A permissible limit has been laid down for fluoride therefore analysis of fluoride is mandatory in drinking water. Our fluoride water test is one of its kinds and works on the titrimetric principle. The end point is a clear yellow.

Code Range No of test
AE-210 0.1-2.0, 1-20 mg/l as Fluoride 500

Sulphite Test Kit

Sulphite is not usually present in surface waters. If sulphite is discharged in effluents or from domestic wastewaters, it readily oxidizes to sulphate. Sodium sulphite, the most common form of sulphite is an excellent reducing agent and is commonly used as an oxygen scavenger to control corrosion. Sulphite concentrations in boiler and process waters must be monitored regularly to protect the systems. Our sulphite test kit works when sulphite in salt form has been added to waters. It is a tritation method, easy to use and easy to read.

Code Range No of test
AE-206 5-100 mg/l as na2so3 300

Nitrate Test Kit

Nitrates are inorganic salts that occur as a natural or manmade contaminants in drinking water. High nitrate levels indicate the presence of other pollutants, such as bacteria or pesticides, as these follow the same path as the nitrate into the water supply. Our nitrate water test kit is based on a colour comparison method. It is a very sensitive one and giving distinct colours which are easily comparable with the chart provided.

Code Range No of test
AE-308 0.5,1.0,2.5,5,7.5,10,20,30,40,50 mg/l as NO3 400

Sulphate Test Kit

Sulphate is a constituent of TDS and may form salts with sodium, potassium, magnesium and other cations. Sulphate (so4-2) is widely distributed in nature and may be present in natural waters at concentrations ranging from a few to several hundred milligrams per litre. Sulphate can cause scale build-up in water pipes. Sulphates are also food for the Anaerobic slime formers the sulphate reducing bacteria which are responsible for pitting type of corrosion in pipes. The AQUASOL water test kit for sulphate is based on titrimetry and is extremely user friendly.

Code Range No of test
AE-209 10-200, 50-1000 mg/l as Sulphate 350

Phosphonate Test kit

Phosphonates a are a class of chelating agents and scale inhibitors, used in household cleaning products, personal care products, institutional cleaners and industrial cleaning processes and water treatment additives in various applications. They play an important role in boiler, cooling and process water treatment. The phosphonate water testing kit is available for both low and high ranges and used by boiler maintenance personnel frequently.

Code Range No of test
AE-401 5-100 & 50-1000 mg/l as HEDP 300
AE-411 2-40 & 5-100 mg/l as phosphonate 300

Orthophosphate Test Kit

Orthophosphate is a commonly used corrosion inhibitor that is added to finished drinking water. It works by forming a protective coat inside pipes in the distribution systems and in customer homes to prevent lead from leaching into drinking water. The other name is phosphoric acid, and it is used to control alkalinity/acidity in foods and beverages. It is a vital parameter for boiler, cooling and process water treatment. This water testing kit is again based on colour comparison. This kit is available in both low and high ranges.

Code Range No of test
AE-301 0.0,5,10,20,30,40 mg/l as po4 100
AE-311 0.1,0.2,0.5,1.0,2.5,5.0,7.5,10 mg/l as po4 500

Turbidity Test Kit

Turbidity is a principal physical characteristic of water. It is caused by suspended matter or impurities that interfere with the clarity of the water. These include clay, silt, finely divided inorganic and organic matter, soluble coloured organic compounds, and plankton and other microscopic organisms. Turbidity is the measure of relative clarity of a liquid. Clarity is required for drinking water and in manufacturing uses. This AQUASOL water turbidity test kit is simple and adequate. It has been designed for “onsite “use. It suffices its purpose and helps regular monitoring.

Code Range
AE-300 1 , 5 , 10 , 20 ntu

Tannin Test Kit

Tannin is a natural organic material that is the by product of nature’s fermentation process, created as water passes through peaty soil and decaying vegetation. Tannins create a light yellow to dark brown discoloration of the water, and cause yellow staining on fabrics, fixtures, and laundry. Tannin based formulations are used for prevention of scale and corrosion in steam boilers, closed cooling systems and steam locomotives. The tannin test kit is a titrimetric one and has reagents for 2 ranges in the same kit, making it portable and user friendly.

Code Range No of test
AE-2tn 5-100, 25-500 mg/l as tannin 300

Hydrazine Test Kit

Hydrazine is used as an oxygen scavenger for high pressure boilers in power plants and other industries to reduce corrosion of metal pipes and fittings. Our hydrazine water test kit is regular used for high pressure boiler monitoring, the results are easily discernable and can be used by shop floor personnel.

Code Range No of test
AE-304 0.1,0.2,0.3,0.4,0.5,0.75 mg/l as hydrazine 200

Copper Test Kit

Copper is a metal that exists in the environment as a mineral in rocks and soil. It is commonly found at low levels in natural water bodies. Consumption of high levels of copper can cause nausea, vomiting, diarrhoea, gastric complaints and headaches. Copper salts are used to control algAE. The copper water test kit is based on colour comparison and can do 250 tests .

Code Range No of test
AE-310 0,0.5,1.0,1.5,2.0,2.5 mg/l as copper 250

Chlorine Dioxide Test Kit

Chlorine dioxide is a broad-spectrum micro biocide effective over a wide ph range. Chlorine dioxide is effectively used in the control of microbiological growths in industrial cooling waters under conditions unfavorable to chlorine. This water test is a titrimetric one, generally used by cooling tower maintenance personnel to monitor residuals of the oxidising microbiocide.

Code Range No of test
AE-405 0.2–4.0 mg/l as chlorine dioxide 100

Amine Test Kit

Amines are used as neutralizing agents for condensation water in boiler treatment. This helps to control corrosion. This water test kit is available in two ranges as two separate kits. Both give results in terms of cyclohexamine.

Code Range No of test
AE-402 5-100 & 50-10100 mg/l as cyclohexylamine 300
AE-412 1-20 mg/l as cyclohexylamine 300

Chromate Test Kit

It is produced in pickling and plating operations, anodizing aluminium, leather tanning, manufacturing of paints, dyes and explosives. Chromate is used to inhibit corrosion in open and closed system cooling towers. This AQUASOL water test kit is generally used by paint and dye manufacturers and very rarely for monitoring cooling systems, as with the advent of technology newer safer biocides are being used and chromate has almost left the scene.

Code Range No of test
AE-208 5-100, 25-500 mg/l as chromate 200

Silica Test Kit

Silica (sio2) is an oxide of silicon, and is present in almost all minerals. It is found in surface and well water. Silica is a problem for high pressure boilers, as it exhibits enough volatility that high pressure boilers will have silica carry over to the vapour partition. When the steam pressure is reduced in turbines, silica will precipitate on the blades as a glassy deposit, which reduces efficiency. Measuring silica in water is useful to monitor demineralizer for boiler water treatment. The silica water test is available as 4 different products in very low and very high ranges.

Code Range No of test
AE-302 5,10,20,40,60,80 mg/l as sio2 400
AE-312 0.01,0.025,0.05,0.075,0.1 mg/l as sio2 75
AE-322 0.2,0.4,0.8,1.5,3.0,5.0 mg/l as sio2 100
AE-332 75,100,125,150,175,200 mg/l as sio2 100

Molybdate Test Kit

Formulations containing molybdate are used as corrosion inhibitors in industrial water treatment. In particular, molybdate finds application in closed recirculating systems such as water heating systems and chilled water systems. Since molybdates are widely used in water treatment and industrial processes, testing molybdate is becoming increasingly important for effluents and industrial discharges. This water test kit is a colour comparison one and can give 325 tests in one kit.

Code Range No of test
AE-309 5,10,20,30,40,50 mg/l as MoO4 325

Zinc Test Kit

Zinc is introduced into water naturally by erosion of minerals from rocks and soil, most zinc is introduced into water by artificial pathways such as by-products of steel production coal-fired power stations, or from the burning of waste materials. Zinc is also used in some fertilizers that may leach into groundwater. Zinc is used as a corrosion inhibitor for Cooling water. The zinc water testing system is easy to use and results achieved are fairly accurate.

Code Range No of test
AE-305 0.1,0.25,0.5,1.0,2.5,5.0, 7.5,10.0 mg/l as Zinc 450

Arsenic Test Kit

Arsenic in drinking-water is a hazard to human health. The main source of arsenic in drinking-water is arsenic-rich rocks through which the water has filtered. It may also occur because of mining or industrial activity in some areas. AQUASOL arsenic test kit provides easy-to-use, low-cost method for measuring arsenic levels in water. This water test kit is quite novel and one its kind. It is the effort of our in house R&D.

Code Range No of test
AE-408 0.0, 0.05,0.1,0.2,0.5,1.0,2.0,3.0 mg/l as Arsenic 100

Product Video:  

Hydrogen Peroxide Test Kit

The corrosiveness of process water due to hydrogen peroxide depends on the amount of dissolved oxygen that is produced. Oxygen corrodes iron-containing metals. Hydrogen peroxide is used as a disinfectant. H2o2 is used to disinfect drinking water. It is also used to combat excessive microbial growth in water systems and cooling towers. AQUASOL hydrogen peroxide test kit helps to estimate the concentration of h2o2 in water.

Code Range No of test
AE-HP 5-100 & 25-500 mg/l as H2O2 300